Chemical

Optimization of a utility - Compressed air

Consumptions

  • 1M€ / year for energy consumption of the compressors
  • Consumption 13GWh / year

Challenges

  • Optimization of the sequencing of the 6 variable and fixed speed compressors.
  • Dynamic model that adjusts as soon as a new air flow rate is requested.

Savings

  • 80,000€ per year, 8% of savings.